NA200H Communication Module
Category:
- Product Description
- Performance Parameters
-
The DP slave communication module CMM201-0103 has the following features:
Standard PROFIBUS-DP slave interface: DP-VO/V1 protocol, compliant with IEC 61158 and the Chinese national standard GB/T 20540-2006: Part 3—Fieldbus for Measurement and Control Digital Data Communication in Industrial Control Systems.
The baud rate is adjustable, with a maximum baud rate of 12M.
The maximum number of slave stations that can be connected to a Profibus bus is 30.
Maximum expansion I/O modules: 7 expansion I/O modules;
Smart module with powerful self-diagnosis capabilities; when a fault occurs during module operation, it can automatically reset and restart itself.
The unique data security output function gives the control device enhanced security features.
Comprehensive LED indicators: Includes comprehensive LEDs for power, module activation, module operation, fault status, PROFIBUS bus operation, and fault detection.The serial communication module CMM201-0201 has the following features:
Independently complete communication tasks, enabling data exchange both with the NA200H CPU and with external serial port devices.
Two extended RS485 serial ports that support both internal Modbus master communication and custom protocol communication, with a selectable baud rate range of 2400 to 115,200 bps.
An extended RS232 serial port that does not support programming; it only supports communication and program downloading.
Divide the input and output areas: it can simultaneously support up to 256 digital inputs, 256 digital outputs, 120 analog inputs, and 120 analog outputs, with each input and output area not exceeding 240 bytes.The serial communication module CMM201-0211 has the following features:
Independently complete communication tasks, enabling data exchange both with the NA200H CPU and with external serial port devices.
Two extended RS485 serial ports that support both internal Modbus master communication and custom protocol communication, with a selectable baud rate range of 2400 to 115,200 bps.
An extended RS232 serial port that does not support programming, but only supports communication and program downloading.
One RJ45 Ethernet interface, supporting configuration, monitoring, and debugging, or Modbus TCP master communication (DIP switch control);
Divide the input and output areas: it can simultaneously support up to 256 digital inputs, 256 digital outputs, 120 analog inputs, and 120 analog outputs, with each input and output area not exceeding 240 bytes.The dual-channel CAN communication module CMM201-0204 features the following characteristics:
Dual CAN interfaces, custom protocol communication;
Baud rate freely programmable, supporting basic baud rates from 5K to 1000K;
The maximum input for internal communication is 120 characters (240 bytes), and the output is also 120 characters (240 bytes).
Smart module with powerful self-diagnosis capabilities; when a fault occurs during module operation, it can automatically reset and restart itself.
The unique data security output function gives the control device enhanced security features.
Comprehensive LED indicators: Power, module operation, fault, and CAN bus transceiver—all fully indicated by LEDs.The Ethernet communication module CMM201-0105 has the following features:
Supports the standard MODBUS TCP slave protocol;
Supports up to 8 master stations accessing data simultaneously;
The communication rate is 100 Mbps;
The unique data security output function gives the control device enhanced security features.
Comprehensive LED indicators: LEDs indicating module operation, faults, Ethernet communication, and more;
Supports hot-swapping.*The content of this document is subject to change as the product undergoes further development. The right of interpretation rests with Aotuo Technology Co., Ltd.
-
Module model
CMM201-0103
CMM201-0201 CMM201-0211 CMM201-0204 CMM201-0105 Power consumption
2.0W/5V
2W/5V 2W/5V 2.25W/5V 2W/5V Current consumption
400mA/5V
400mA/5V 400mA/5V 450mA/5V 400mA/5V Number of bus interfaces
1
2 3 2 1 (Can communicate with up to 8 MODBUS TCP master stations simultaneously) Bus interface type
Profibus DP slave
RS485 2 RS485 ports, 1 RJ45 port CAN master station Ethernet (factory default IP is 192.168.3.110) Supports communication baud rates
9600~12 Mbps
2400~115200 bps
2400~115200 bps
5–1000 kbps
10M--100M
Interface Isolation
Optical isolation 2500V rms
Optical isolation 2500V rms
Optical isolation 2500V rms
Optical isolation 2500V rms
Optical isolation 2500V rms
Programming-driven
The manufacturer provides the GSD file.
The manufacturer provides the GSD file.
The manufacturer provides the GSD file.
The manufacturer provides the GSD file.
The manufacturer provides the GSD file.
Operating temperature
10℃~+55℃ (standard model)
-40℃~+70℃ (wide-temperature model)10℃~+55℃ (standard model)
-40℃~+70℃ (wide-temperature model)10℃~+55℃ (standard model)
-40℃~+70℃ (wide-temperature model)10℃~+55℃ (standard model)
-40℃~+70℃ (wide-temperature model)10℃~+55℃ (standard model)
-40℃~+70℃ (wide-temperature model)Storage temperature
-40℃~+70℃ (Standard Type)
-45℃~+80℃ (wide temperature range)-40℃~+70℃ (Standard Type)
-45℃~+80℃ (wide temperature range)-40℃~+70℃ (Standard Type)
-45℃~+80℃ (wide temperature range)-40℃~+70℃ (Standard Type)
-45℃~+80℃ (wide temperature range)-40℃~+70℃ (Standard Type)
-45℃~+80℃ (wide temperature range)Relative humidity
5% to 95%, non-condensing
5% to 95%, non-condensing
5% to 95%, non-condensing
5% to 95%, non-condensing
5% to 95%, non-condensing
Weight (g)
180
180
180
180
180
Width × Height × Depth (mm)
75X90X75
75X90X75
75X90X75
75X90X75
75X90X75
*The content of this document is subject to change as the product undergoes further development. The right of interpretation rests with Aotuo Technology Co., Ltd.